€117,-* Goods to order; Europe 21 Days, RoW 24 Days
Unit price: €117,00 / Piece
* Incl. tax Excl. Shipping costs
48 VDC to 12 VDC Converter isolated... Show more
These devices are housed in a rugged, corrosion resistant anodized aluminum housing. The low mass of the surface mount technology components offer excellent resistance to shock and vibration, thereby improving the reliability of these products will continue to increase. For simplicity during installation and acceleration for debugging the output is displayed to the transducer by a green LED. With the T-shaped mounting bracket, the power supply can be installed quickly and easily.
Input voltage range | Auto-Select, 85-135 VAC and 170-265 VAC, 47-440Hz |
Output voltage options | 13,6 VDC, 27,2 VDC or 54,4 VDC, as ordered . Worst case limits are +/- 4% |
Output noise | <50mV pk-pk at continuous load |
Power Conversion Efficiency | Typically 85% |
Isolation between input and case/output Isolation casework to ground | 1,5 kVAC/3,0 kVAC rms, Connected directly to mains input ground |
Normal operating temperature | -25ºC to +30ºC to meet this specification table +30ºC to +70ºC de-rate linearly to 0A |
Storage Temperature | -25ºC to +100ºC |
Max case temperature | 70ºC at full load with 25ºC ambient |
Operating humidity | 95% max, non-condensing |
Casework | Anodized aluminium |
Connections: Input OutputGround | IEC-320 C14 socket, C13 terminated cordset 6.3mm push-on blade terminals Stud with crimp eyelet, adjacent to input |
Output Indicator | Green LED adjacent to output terminals |
Mounting Method | ‘ Click ‘n’ Fit’ mounting clip or rubber feet. DIN rails clips available as a special order |
Safe area protection: Over Current Over heat Over voltage TransientsCatastrophic failure | Limited by current sensing circuit Limited by temperature sensing circuit Protected by independent shut down circuit Protected by filters and rugged component selection |
Approvals | 2004/108/EC The general EMC directive 2006/95/EC The low voltage directive 93/68/EEC The CE marking directive |
Tested to | EN50081-1, EN50082-1, EN55014-1, EN61000-3-3, EN60950, EN60945, UL1950, CSA950-95, VDE0805 |
Markings | CE |