Input voltage range | 12 VDC nominal (10.0V-15.0V) |
Output voltage | 27,2 VDC +/-5% at extremes of temperature, load, input tolerance, etc. |
Continuous current rating | 3 A - 25 A depending on model. |
Intermittent rating | Continuous rating +20%, taken for a maximum of 2 minutes followed by 8 minutes rest |
Transient voltage protection | Meets ISO7637-2 International standard for 24 VDC commercial vehicles |
Electrostatic voltage protection | Meets ISO10605, ISO14892, >8 kV contact, 15 kV discharge |
Output noise | <100mV pk-pk at continuous load. |
Off load current (quiescent current) | <20m A (400 W and 600 W versions enable off), less than 100 mA (72-240 W units) |
Power conversion efficiency | Typically: 93% |
Operating temperature | -25ºC to +30ºC to meet this specification table |
| +30ºC to +80ºC de rate linearly to 0 A |
Storage temperature | -25ºC to +70ºC |
Operating humidity | 95% max., non-condensing |
Casework | Anodised aluminium, glass filled polycarbonate, dust water and impact resistance to IP533. |
| Ruggedized versions also available to IP65 |
Connections | Four 6,3 mm push on flat blade connectors (72-240 W) |
| Five terminal connector with screw tightening with mating half supplied (400 and 600 W units) |
Output indicator | Green LED adjacent to output terminals |
Mounting method | ‘Click ‘n fit mounting clip, fitted separately using 3 hole fixing (4 hole on 400 and 600 W) |
Safe area protection: Over current | Limited by current sensing circuit |
Over heat | Limited by temperature sensing circuit |
Transients | Protected by filters and rugged component selection |
Input / Output over voltage protection | Controlled by internal circuitry |
Catastrophic failure | Protected by internal input and output fuses |
Approvals | 2004/108/EC The general EMC directive |
| 2006/96/EC The automotive directive |
| 93/68/EEC The CE marking directive |
Markings | CE and e marked |